Quickstart Guide of VS-GW1600-20G Connect with 3CX Server

This document applies to OpenVox GSM Gateway WGW1002,VS-GW1202-4/8G and VS-GW1600 series.

There are two RJ45 Network ports, ETH1 and ETH2. If you choose ETH1, you can access Board 1 only, and access other boards with the same IP address, different port numbers. This will help to avoid IP conflict. If you choose ETH2, you can access different Boards with different IP addresses. But there is only one RJ45 Network port on WGW1002.

VoxStack provides 2 working modes: Stand-alone and Cluster.

  • Stand-alone: A single IP address manages one GSM modules (4 ports).
Stack NumIPUsernamePassword
1172.16.99.1adminadmin
2172.16.99.2adminadmin
3172.16.99.3adminadmin
4172.16.99.4adminadmin
5172.16.99.5adminadmin
  • Cluster: A single IP address manages up to 5 GSM modules (up to 20 ports).
                                  
                                  Default IP: 172.16.99.1 
                                  User Name: admin
                                  Password: admin

 

 

If your system topology like the figure described, please enter the gateway default IP address In your browser to login web, and click “NETWORK—>LAN Settings” to set network parameters such as IP.

Save your changes. Please type in your DNS server in “DNS Server Address”.

 

Please select “SIP—>SIP Endpoints—>Add New SIP Endpoint” to set SIP trunk. The following figure shows detail information about how to set it.

About other parameters in SIP, please set by your requirements for there is no need to set them in simple calls.

Click “ROUTING—> Call Routing Rules—> New Call Routing Rule” to set outbound and inbound routing rules like the following:

Save the inbound call routing rules, please set the outbound rules as introduced. In order to make all calls successfully, please enable and set failover function in advanced routing rule like that:

Please select “VOIP/PSTN Gateways—> Add Gateway” to create a SIP trunk:

After that, please click the next button to the following page :

About other options, you can set or skip by your requirements until go to the following web which means SIP trunk is registered.

 

Click Inbound Rules—>Add DID to set inbound rules

 

Click Outbound Rules—>Add Outbound to set outbound rules

Taking advantage of SIP software such as Xlite, eyeBeam to register a SIP extension(301). After all above steps, you can try to make calls and send SMS.


Front Panel

LED IndicatorColorStatus
Network Status LEDGreen and FlashNetwork Connected
Signal Status LED



Green and FlashModule Initiating
Red and FlashNo SIM Card
Red and No-flashWorst Signal Quality
Yellow and No-flashMedium Signal Quality
Green and No-flashBest Signal Quality
Call Status LEDFlash (0.25s)Communicating
BlindNormal
Running Status LEDGreen and Flash(0.5s)Work Normally
Power IndicatorAlways GreenSupply Power
During reset, all LED indicators flash.